> [!info] **Use silicone dampening balls between bulkhead/gimbal interface**
> - Silicone balls must be tuned to adjust effective stiffness, dampening
> - Soft isolation: better at reducing high-frequency, but allows more camera movement
> - Stiff isolation: better at holding camera in position during maneuvers, but transmits more vibration
> maybe use 2 balls instead of 3?
# Testing
## Measure baseline vibration
1. Redesign system to attach an accelerometer (connected to DAQ) near camera mounting location
2. Mount to shaker oscillator (available @ ME equipment inventory)
3. Complete baseline frequency measurement
## Perform FTT Analysis
Initially use mass-spring-dampener model (single D.O.F). Governing eqn. for acceleration transmission magnitude is
$
T(f)=\sqrt{ \frac{1+(2\zeta r)^2}{(1-r^2)^2+(2\zeta r)^2} }
$
$
r=\frac{f}{f_{n}}\quad f_{n}=\frac{1}{2\pi}\sqrt{ \frac{k}{m} }\quad\zeta=\frac{c}{2\sqrt{ km }}
$
Then adjust dampening manually before using ML