- Pumps change pressure from in -> outlet, flowrate doesn't change - Fluid enters thru center at impeller, gets thrown to side, increasing both KE & area -> pressure increase (for) - Types of fluid machinery 1. Those that do work on the fluid $(H_{S}>0)$ - Pumps: used for liquid - Fans: used for gases/vapors; $\Delta p<$ a few inches of $H_{2}O$ - Fans: used for gases/vapors; a few inches of $H_{2}O<\Delta p<1\text{ atm}$ - Compressors: used for gases/vapors, a few inches of $H_{2}O<\Delta p<1\text{ atm}$ 2. Those that extract work from the fluid (turbine) 1. Positive displacement pumps 1. Force fluid movement using $\Delta V$ (volume) 2. Produce periodic flow rate 3. Large $\Delta p,$ small $Q$ 2. Displacement pumps (jet, axial/radial, EM pumps) - No closed volumes as in PDPs - $\Delta p$ due to changei n fluid momentumn - $\Delta p_{DP}<\Delta p_{PDP}$ - $Q_{DP}>Q_{PDP}$