![[Pasted image 20261114204847.png|right|300]]Cavitation occurs when local pressure in a liquid drops below its vapor pressure, forming vapor bubbles. As the liquid moves into a higher-pressure region, the bubbles collapse. This can cause noise, vibration, reduced pump performance, and damage to nearby surfaces - Liquid turns into vapor due to low pressure, moves further downstream (in pocket) to higher pressure, causing collapse, shockwave which produces a jet of water which damages blade - Net positive suction head $NPSH$ quantifies whether or not a pump will cavitate - Net positive suction head required $NPSHR$ is the minimum suction head a pump needs to limit cavitation at a specified flow rate - $NPSHA$ is pipe system property, amount the system provides to pump $ NPSH\equiv\left( \frac{p}{\rho g} +\frac{\bar{V}^2}{2g}\right)-\frac{p_{v}}{\rho g} $ - Make sure to setup datum CSYS at inlet to neglect $\Delta h,$ $\left( \frac{p}{\rho g}+\frac{\bar{V}^2}{2g} \right)_{S}$ is total head available at suction side (lowest $p$) - Assumed turbulent -> $\alpha=1$ - $p_{v}$ is vapor pressure - Be sure to make both pressure quantities either absolute or gauge >[!info] Finding $NPSHA$ >![[Pasted image 20261114210035.png|right|250]] >$ > \text{EBE: }\left( \frac{p}{\rho g}+\frac{\alpha \bar{V}^2}{2g}+z \right)_{2}=(\dots)_{1}-H_{L_{1\to{2}}}+H_{S_{1\to{2}}} >$ >$ > p_{1}=p_{atm}\quad \bar{V}_{1}=0 \quad H_{S_{1\to{2}}}=0\quad \alpha_{1}=1 \\ p_{2}=p_{s}\quad \bar{V}_{2}=\bar{V}_{S}\quad H_{L_{1\to_{2}}}=H_{L_{1\to_{2}}}\quad \alpha_{2}=1 >$ > >$ > \left( \frac{p}{\rho g}+\frac{\bar{V}^2}{2g} \right)_{2}=z_{1}-z_{2}-H_{L_{1\to 2}}+\frac{p_{atm}}{\rho g} >$ >$ > \left( \frac{p}{\rho g} \right)+\frac{\bar{V}^2}{2g})_{2}-\frac{pv}{\rho g}= \frac{p_{atm}-p_{v}}{\rho g}-H_{L_{1\to 2}}-h=NPSHA >$ > - To optimize, minimize head losses & distance between free surface and height > - Increasing $\bar{V}$ will decrease $NPSHA$ because $H_{L}=\sum k_{i} \frac{\bar{V}_{i}^2}{2}$